Technical Data
Input data5.0-1 UNI6.0-1 UNI7.5-1 UNI
Recommended PV power (kWp)4.25 - 5.755.10 - 6.906.35 - 8.60
MPPT voltage range230 - 500 V230 - 500 V230 - 500 V
Max. input voltage range
(at 1000 W/m² 14 F (-10 C) in open circuit operation)600 V600 V600 V
Nominal input current13.8 A16.6 A20.7 A
Max. usable input current23.4 A28.1 A35.1 A
Admissible conductor size (DC)No. 14-6 AWGNo. 14-6 AWGNo. 14-6 AWG
Output data5.0-1 UNI6.0-1 UNI7.5-1 UNI
Nominal output power (PAC nom)5,000 W6,000 W7,500 W
Max. continuous output power
104 F (40 C) 208 V / 240 V / 277 V5,000 W6,000 W7,500 W
Nominal AC output voltage208 V / 240 V / 277 V208 V / 240 V / 277 V208 V / 240 V / 277 V
Operating AC voltage range (default)
208 V
240 V
277 V
183 - 229 V (-12 / 10%)
211 - 264 V (-12 / 10%)
244 - 305 V (-12 / 10%)
183 - 229 V (-12 / 10%)
211 - 264 V (-12 / 10%)
244 - 305 V (-12 / 10%)
183 - 229 V (-12 / 10%)
211 - 264 V (-12 / 10%)
244 - 305 V (-12 / 10%)
Maximum continuous output current
208 V
240 V
277 V
24.0 A
20.8 A
18.1 A
28.8 A
25.0 A
21.7 A
36.1 A
31.3 A
27.1 A
Admissible conductor size (AC)No. 14 - 4 AWGNo. 14 - 4 AWGNo. 14 - 4 AWG
Max. continuous utility back feed current0 A0 A0 A
Nominal frequency60 Hz60 Hz60 Hz
Operating frequency range59.3 - 60.5 Hz59.3 - 60.5 Hz59.3 - 60.5 Hz
Total harmonic distortion< 3%< 3%< 3%
Power factor111
General data5.0-1 UNI6.0-1 UNI7.5-1 UNI
Max. efficiency96.2%96.2%96.2%
CEC Efficiency
208 V
240 V
277 V
95.5%
95.5%
96.0%
95.5%
96.0%
96.0%
95.5%
96.0%
96.0%
MPP adaption efficiency> 99.9%> 99.9%> 99.9%
Consumption in standby mode (at night)< 1 W< 1 W< 1 W
Consumption during operation15 W15 W15 W
CoolingControlled forced ventilation, variable speed fan
Enclosure TypeNEMA 3RNEMA 3RNEMA 3R
Unit Dimensions (W x H x D)17.1 x 36.5 x 9.6 in.17.1 x 36.5 x 9.6 in.17.1 x 36.5 x 9.6 in.
Power stage weight57 lbs. (26 kg)57 lbs. (26 kg)57 lbs. (26 kg)
Wiring compartment weight (C box)24 lbs. (11 kg)24 lbs. (11 kg)24 lbs. (11 kg)
Admissible ambient operating temperature-13 to 131 F (-25 to 55 C)-13 to 131 F (-25 to 55 C)-13 to 131 F (-25 to 55 C)
Admissible ambient storage temperature-40 to 131 F (-40 to 55 C)-40 to 131 F (-40 to 55 C)-40 to 131 F (-40 to 55 C)
ComplianceUL 1741-2010, IEEE 1547-2003, IEEE 1547.1, UL 1699B-2013, ANSI/IEEE C62.41, FCC Part 15 A & B, NEC Article 690, C22. 2 No. 107.1-01 (Sept. 2011) California Solar Initiative - Program Handbook - Appendix C: Inverter Integral 5% Meter Performance Specification,
CSA TIL M-07 Issue 1-2013
Advanced grid featuresActive and reactive power control, low voltage ride-through
Safety equipment5.0-1 UNI6.0-1 UNI7.5-1 UNI
Arc fault circuit protectionInternal AFCI (Arc Fault Circuit Interrupter); in accordance with UL 1699B Outline of Investigation for Photovoltaic (PV) DC Arc-Fault Circuit Protection (Issue Number 2, January 14, 2013), CSA TIL M-07 Issue 1-2013
Ground fault protectionInternal GFDI (Ground Fault Detector/Interrupter); in accordance with UL 1741-2010 and NEC Art. 690
DC reverse polarity protectionInternal diode
Anti-islandingInternal; in accordance with UL 1741-2010, IEEE 1547-2003 and NEC
Over temperatureOutput power derating / active cooling
-