- PRODUCTS
- >
- SRNE
- >
- SRNE 60 Amp MPPT Charge Controller with 250 Amp inverter breaker & two solar breakers with Two Lightning Arrestor
SRNE 60 Amp MPPT Charge Controller with 250 Amp inverter breaker & two solar breakers with Two Lightning Arrestor
Features for 60 Amp SRNE Solar Charge Controller
- Current Limiting charge mode, when the PV panel is oversized and charge current exceeds the rated current, the controller will lower the charging power which enables the system to work under the rated current.
- 12V/24V/36V/48V auto detect
- Data Storage span can reach 5 Years
- Read or set controllers parameters with software interface cable and monitor the system status
- Built-in temperature sensor with temperature compensation mode.
- TVS Lighting protection
- Over-charge, over-discharge, over-load, over-heat, the battery reverses connection protection.
Operating Voltage: 12V/24V/36V/48V (Automatic Detection)
Max Input Voltage of PV Panel: < 150V
No-load loss: 0.7W~1.5W
Max Solar Power Input: 800W (12V) / 1600W (24V) / 2400W (36V) / 3200W (48V)
Stand by self consumption: <20mA
Charge current: 60A
Transfer efficiency: > 98%
MPPT tracing efficiency: > 99%
Over voltage protection: 16V~17V ; * nV
Limit charge voltage: 15.5V~16V ; * nV
Equalizing charge voltage: 15.0~15.5V ; * nV (25°C)
Equalizing charge interval: 3 ~ 30 days
Bulk charge voltage: 14.0V ~ 15.0V; * nV (25°C)
Bulk charge return voltage: 12.3V ~ 14.0V : * nV (25°C)
Float charge voltage: 13.2V ~ 14.0V ; * nV (25°C)
Over discharge voltage: 9.7V ~ 11.8V ; * nV
Temperature compensation: -4.0mV / °C / 2V
Over temperature protection: Yes
Light-operated open voltage: 5V
Light-operated close voltage: 6V
Light operated delay time: 5min
Device address: 1 ~ 16
FITTING AND CONSTRUCTION
IP Rating: IP32
Max wiring dimension: 25mm2
Working temperature: -35°C ~ ?°C
Dimensions: 286.7 x 170 x 128mm
Weight: 4.2Kg
________________________________
Midnite Solar
Mini DC Disconnect
An affordable DC breaker box, the Mini DC Disconnect from Midnite Solar includes the following features:
- Din rail to accommodate up to five 125 VDC breakers
- Mounting for shunt and charge controller
- ETL listed for the USA and Canada
- Bonded battery/inverter negative tie point
- Equipment ground bus bar
- Aluminum enclosure with full compliment of conduit knock outs
____________________________
DELTA LA302R AC LIGHTNING ARRESTOR, SINGLE PHASE (3-WIRE)
Rapid response, high current Delta Lightning Arrestors help prevent damage to computers and other electronic equipment. The Delta LA Series handles the big surges, like lightning up to 50,000 amps, passing them harmlessly to the ground.
While it is not possible to achieve 100% protection, Delta units will greatly reduce problems due to lightning, power surges and voltage spikes. The LA302R model for light duty 120-250VAC, single phase systems (three wire service) can be used for applications where two hot wires of a single phase system are to be protected.
DELTA ARRESTORS:
- employ a non-conductive base to prevent a blown arrestor from creating a shock hazard
- do not cover adjacent equipment with carbon dust on failing, preventing damage to other equipment
- always fail "clear" to permit continued use of the power system
- are based on a silicon material to provide quicker operation at lower conduction resistance
- will pass a large number of high-energy surges and half-cycle spikes prior to failing
- feature extra long leads to ease installation
- have locknut and bushing furnished
- are available in a variety of voltages or number of poles
- ___________________________________________
Delta
DC Lightning Arrestor
3 Wire, 500VDC
LA 302DCRapid response, high current Delta DC Lightning Arrestors protect your sensitive solar or wind energy systems from nearby lightning strikes. The Delta LA Series handles the big surges, like lightning up to 50,000 amps, passing them harmlessly to the ground. The once optional vent valve is now installed on every Delta DC lightning arrestor, which will keep the case from rupturing in the event of the arrestor taking a strike. A small vent on the bottom of the case will open.
While it is not possible to achieve 100% protection, Delta units will greatly reduce problems due to lightning, power surges and voltage spikes. The LA302DC model is ideal for photovoltaic and other limited current DC applications.
DELTA ARRESTORS:
- employ a non-conductive base to prevent a blown arrestor from creating a shock hazard
- do not cover adjacent equipment with carbon dust on failing, preventing damage to other equipment
- always fail "clear" to permit continued use of the power system
- are based on a silicon material to provide quicker operation at lower conduction resistance
- will pass a large number of high-energy surges and half-cycle spikes prior to failing
- feature extra long leads to ease installation
- have locknut and bushing furnished