- PRODUCTS
- >
- POWER INVERTERS
- >
- SRNE 5000 W 48 volt SINE WAVE HYBRID INVERTER/CHARGER + 80 A MPPT (4200 Watt) + 40 AMP AC CHARGER/40 Amp TRANSFER SWITCH
SRNE 5000 W 48 volt SINE WAVE HYBRID INVERTER/CHARGER + 80 A MPPT (4200 Watt) + 40 AMP AC CHARGER/40 Amp TRANSFER SWITCH
HF4850U80-H 5000 Watt 80 Amp MPPT with Max PV input of 500 Volt and 40 AC charger/Transfer Switch
HF48-H series is a new hybrid solar charge inverter, which integrates solar energy storage &means charging energy storage and AC sine wave output.
Thanks to DSP control and advanced control algorithm, it has high response speed, high reliability and high industrial standard.
1. It adopts full-digital double closed loop control, combined with advanced SPWM technology to output pure sine wave.
2. Two output modes: mains electricity bypass and inverter output; uninterrupted power supply.
3. Four charging modes: PV Only, Mains Electricity Priority, PV Priority and PV&Mains Electricity hybrid charging.
4. Advanced MPPT technology with 99.9% efficiency.
5. Wide MPPT voltage range: 120-450V.
6. Individually on load capacity.
7. It comes with double lithium battery activation modes: mains and PV, and supports lead-acid battery and lithium battery access.
8. Comes with a LCD display and 3 LED indicators that can clearly indicate the status and data.
9. Rocker switch for AC output control.
10. Power saving mode, reduce no-load loss.
11. Intelligent variable-speed fan to efficiently dissipate heat and extend system lifespan.
12. All-round protection for solar panels includes overload and short circuit protection, under-voltage and over-voltage protection and reverse polarity protection.
Model
HF4850U80-H
AC mode
Rated input voltage
120 Volt AC
Input voltage range
(100-120 Vac) ±2%
Frequency
60Hz (auto-sensing)
Frequency Range
47±0.3Hz ~ 55±0.3Hz (50Hz)/57±0.3Hz ~ 65±0.3Hz (60Hz);
Overload/short circuit protection
Breaker
Efficiency
>95%
Conversion time (bypass and inverter)
10ms (Typical value)
AC reverse protection
yes
Maximum bypass overload current
40A
Inverting mode
Output voltage waveform
Pure sine wave
Rated output power(VA)
5000
Rated output power(W)
5000
Power factor
1
Rated output voltage (Vac)
110Vac
Output voltage error
±5%
Output frequency range (Hz)
60Hz ± 0.3Hz
Efficiency
>90%
Overload protection
(102%
(125%
Load>150% ±10%: reporting error and turn off the output after 5 seconds;
Peak power
10000VA
Loaded motor capacity
4HP
Output short-circuit protection
Breaker
Specification of bypass breaker
40A
Rated battery input voltage
48V (minimum start voltage 44V)
Battery voltage range
40.0Vdc~60Vdc ± 0.6Vdc (under voltage alarm/turnoff voltage/overvoltage alarm/overvoltage restoration…settable LCD screen)
Power saving mode
Load ≤25W
AC charge
Battery type
Lead acid or lithium battery
Maximum charge current
60A
Charge current error
± 5Adc
Charge voltage range
40~60Vdc
Short-circuit protection
Circuit breaker and blown fuse
Breaker specification
40A
Overcharge protection
Alarm and turn off charging after 1 minute
Solar charge
Maximum PV open circuit voltage
500Vdc
PV operation voltage range
120-500Vdc
MPPT voltage range
120-450Vdc
Battery voltage range
40-60Vdc
Maximum output power
5000W
Charge current range of solar energy (settable)
0-80A
Charge short-circuit protection
Blown fuse
Wiring protection
Reverse polarity protection
Authentication specification
Specification authentication
CE(IEC/EN62109-1,-2)、ROHS2.0
EMC authentication grade
EN61000
Operation temperature range
-15°C to 55°C
Storage temperature range
-25°C ~ 60°C
Humidity range
5% to 95% (Conformal coating protection)
Noise
≤60dB
Thermal dissipation
Forced air cooling, variable speed of fan
Communication interface
USB/RS485(Bluetooth/WiFi/GPRS)/Dry node control
Dimension (L*W*D)
426mm*322mm*126mm
Weight (kg)
11